icon_wind.png

Wind

Anemometer to measure the wind speed and the wind direction

Wind Direction, Heavy-Duty

TF4123

Wind Direction Sensor; heavy duty design with CNC-manufactured metal housing (seawater resistant aluminium alloy Al Mg  Si 1, black anodized). Special rugged design with improved dynamic features  basing on high precision bearings and optimised balancing.

This sensor is designed for the acquisition and electronic transmission of wind direction data. It is suitable for applications in the field of meteorology and environmental monitoring, e. g. for automatic weather stations, at airports, on research vessels, at industrial sites, for mobile measuring systems etc..

The instrument’s rugged construction and its dust- and water repellent surface, as well as the optional high performance heating enable heavy duty applications like wind energy measurement or operation under severe climatic conditions.

Thanks to various simultaneously usable outputs and further options there is a wide range of measuring tasks (refer to “Variations”).

When moving the wind vane, the wheel of the angular encoder is turned so that, depending on the wind direction, a corresponding digital signal is supplied. The subsequent electronic circuitry converts this signal to a serial output, resp. to additional analog signals (refer to "Technical Specifications"). The serial data output (TTL) corresponds an RS 232 structure, with 600 Bd, 8 bit, 1 start bit, 2 stop bit, no parity bit.

  • Technical Specification
  • Variations
  • Measuring range: 360°
  • Threshold at 90° initial deflection: < 0.2 m/s
  • Dampingratio at v = 3 m/s and initial deflection = 15°: < 0.3
  • Compliances: WMO Guide No. 8/7th ed.
    VDI 8786, T.2, 12/2000
    MEASNET
  • Power supply: Type 4123.0000:
    10…30 VDC; < 5 mA at 12 V
    Type 4123.1000:
    10…30 VDC; 35…75 mA at 12 V
  • Output: digital: serial 8 bit Gray code, RS 232 compatible, 600Bd, 8 data bit, 1 startbit, 2 stopbit, no parity, TTL level
    analog: 0...20 mA, 4...20 mA and 3 phase signal for direct con-nection of analog instruments
  • Admissible load: approx. 400 Ohm
  • Heating system: Thermostat controlled, max. 7 W
  • High perf. heating: max. 60 W
  • Operating temperature: -25...+80 °C
    -40…+80 °C with high per-formance heating
  • Ausgangssignal: digital, 8 Bit Gray Code als serielles Datenwort, RS232 kompatibel
    zusätzl. bei Version 4123.1000: analog
    0...20 mA
    4...20 mA
    3-Phasensignal zum Direktanschluss an Analoginstrumente
  • zul. Bürde: ca. 400 Ω
  • Abmessungen: 370 mm hoch, Drehradius der Fahne ca. 350 mm
  • Gewicht: ca. 1,015 kg
  • Befestigung: Zapfen ∅34 x 40 mm
  • Anschluss: Steckverbindung, Metall, Schutzart IP 67
  • Protection class: IP 65, when operated upright
  • Housing material: Aluminium alloy
  • Connection: 12 p. connector, water- and dust proof acc. to IP 67
  • note 4123.0000Sensor for wind direction with serial data output, 8 bit Gray Code, TTL, with built-in heating
  • note 4123.1000Sensor for wind direction with serial data output and build in heating, 8 bit Gray Code, TTL, Analog output 0...20 mA, 4...20 mA incl. 3-phase signal; suitable for analog instruments
  • note 4123.01004123.0000, with high performance heating
  • note 4123.11004123.1000, with high performance heating